Server QOS 8-Bay Guide de l'utilisateur Page 36

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 308
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 35
Virtual Connect domains 36
connUnitPortStatus value Severity
ready
NORMAL
warning
WARNING
failure
CRITICAL
nonparticipating
INFO
initializing
INFO
bypass
INFO
ols
MAJOR
other
INFO
Trap categories and required user role permissions
In general, users with domain role permission can perform any SNMP configuration change operations.
Users with network role permission can perform Ethernet configuration change operations, and users with
storage role permission can perform FC configuration change operations. The following table provides a
summary of trap categories and the required administrative privileges.
Trap Category Domain Network Storage
VC-Enet Port Status
X X
VC-Enet Port Threshold
X X
VC-Enet Other
X X
VC-FC Port Status
X X
VC-FC Other
X X
VCM Legacy
X
VCM Security
X
VCM Domain Status
X
VCM Network Status
X
VCM Fabric Status
X
VCM Profile Status
X
VCM Server Status
X
VCM VC-Enet Status
X
VCM VC-FC Status
X
To enable or disable SNMP on a VC-Enet module, domain or network role permissions are required. To
enable or disable SNMP/SMI-S on a VC-FC module, domain or storage role permissions are required.
Trap severities
The severity of traps sent to each destination can be configured, resulting in only traps of the specified
severities being sent to the destination. The levels are listed below in decreasing order of severity:
CRITICALThe component cannot manage installed VC components.
MAJOROne or more of the component's subsystems is not operating properly, causing serious
disruption to functions.
MINOROne or more of a component's subsystems is not operating properly, causing slight disruption
to functions.
WARNINGThe component has a potential problem.